    Products Current Location: Home > Products  

    UF water filter moduel SRUF-700C

      

    1, PERFORMANCE PARAMETERS Seven - hole
     Membrane Material PVC
     Molecular Weight
     Cut-off     (MWCO)
    100,000 Daltons
     Inner and outer diameters
     of hollow-fiber
    0.9mm/4.2mm
     Membrane fiber type Inside-out hollow-fiber
     Characteristics of
     membrane structure
     Hydrophilic double-compact layers
     External Shape Hollow fiber
    2, APPLICATION CONDITIONS  
     Pre - filtration 50-150 um
     Max turbidity of
     inlet water
    ≤ 15 NTU
     Rated flux 60 – 160 L/M2/H/0.1Mpa
     Running mode  Cross-flow filtration or dead end filtration
     Max inlet water pressure 0.7Mpa
     Pressure difference of
     transmembrane at 20°C (TMP)
    28 – 150 KPa
     Max pressure difference
     of transmembrane
    0.2 MPa
     Applicable PH range 2 – 12
     Applicable temperature  5 °C - 45 °C
     Tolerable continuous
     residual chlorine
    100 PPm
     Tolerable interval
     residual chlorine
    200 PPm
     
    3, BACKWASHING DESIGN  
     Backwashing pressure 0.25 MPa
     Backwashing flow 220 – 300 L/M/H
     Backwashing frequency Every 20 -60 minutes
     Backwashing time 30 – 60 seconds every time
     Frequency of chemically
     enhanced ( CEB )
     Auto adding of additives in
     backwashing is recommended.
     Time of chemically enhanced
     backwashing ( CEB )
    30 – 60 seconds every time
    4, CHEMICALLY WASHING DESIGN  
     Frequency of chemically washing Every 1~4 months or when TMP is over 0.15 MPa
     Pressure of chemically washing 0.15 MPa
     Flow of chemically washing 200 – 250 L/M/H
     Time of chemically washing  60 – 90 minutes every time
     Acid washing chemical  Citric acid or oxalic acid
     ( mixed into solution with PH = 2 )
     Alkali washing chemical  NaOH ( mixed into solution with PH=12)
    5, INDEX OF OUTPUT WATER  
     Turbidity of output water < 0.1 NTU
     Index of silt density < 1.5
     Microorganism, pathogen 99.99 % Removed
         Remarks: 1. Pure water flux is measured with pure water
    at 25°C with inlet water pressure of 0.1MPa.
    2. If water are from surface water,river water or well water and so on,
    pre-treatment shall be done. It is suggested that a 50-150 um precision filter
     shall be equipped to have inlet water with turbidity ≤15NTU.   

     


    Print 】 【 Back

     

    Copyright (C) 2013 SUOAI.COM.CN All Rights Reserved.  闽ICP备2024070064号