| 1, PERFORMANCE PARAMETERS |
Seven - hole |
| Membrane Material |
PVC |
Molecular Weight
Cut-off (MWCO) |
100,000 Daltons |
Inner and outer diameters
of hollow-fiber |
0.9mm/4.2mm |
| Membrane fiber type |
Inside-out hollow-fiber |
Characteristics of
membrane structure |
Hydrophilic double-compact layers |
| External Shape |
Hollow fiber |
| 2, APPLICATION CONDITIONS |
|
| Pre - filtration |
50-150 um |
Max turbidity of
inlet water |
≤ 15 NTU |
| Rated flux |
60 – 160 L/M2/H/0.1Mpa |
| Running mode |
Cross-flow filtration or dead end filtration |
| Max inlet water pressure |
0.7Mpa |
Pressure difference of
transmembrane at 20°C (TMP) |
28 – 150 KPa |
Max pressure difference
of transmembrane |
0.2 MPa |
| Applicable PH range |
2 – 12 |
| Applicable temperature |
5 °C - 45 °C |
Tolerable continuous
residual chlorine |
100 PPm |
Tolerable interval
residual chlorine |
200 PPm |
| |
| 3, BACKWASHING DESIGN |
|
|
| Backwashing pressure |
0.25 MPa |
| Backwashing flow |
220 – 300 L/M/H |
| Backwashing frequency |
Every 20 -60 minutes |
| Backwashing time |
30 – 60 seconds every time |
Frequency of chemically
enhanced ( CEB ) |
Auto adding of additives in
backwashing is recommended. |
Time of chemically enhanced
backwashing ( CEB ) |
30 – 60 seconds every time |
| 4, CHEMICALLY WASHING DESIGN |
|
| Frequency of chemically washing |
Every 1~4 months or when TMP is over 0.15 MPa |
| Pressure of chemically washing |
0.15 MPa |
| Flow of chemically washing |
200 – 250 L/M/H |
| Time of chemically washing |
60 – 90 minutes every time |
| Acid washing chemical |
Citric acid or oxalic acid
( mixed into solution with PH = 2 ) |
| Alkali washing chemical |
NaOH ( mixed into solution with PH=12) |
| 5, INDEX OF OUTPUT WATER |
|
| Turbidity of output water |
< 0.1 NTU |
| Index of silt density |
< 1.5 |
| Microorganism, pathogen |
99.99 % Removed |
| Remarks: |
1. Pure water flux is measured with pure water
at 25°C with inlet water pressure of 0.1MPa. |
2. If water are from surface water,river water or well water and so on,
pre-treatment shall be done. It is suggested that a 50-150 um precision filter
shall be equipped to have inlet water with turbidity ≤15NTU. |